ECU Flash Programming & Bootloader Architecture
Step-by-step diagnostic sequence for ECU firmware updates: RequestDownload (0x34), TransferData (0x36), and RequestTransferExit (0x37).
Technical Specifications
- Governing Standard
- ISO 14229-1 UDS Flash Bootloader (FBL) & DoIP Service 0x38 File Transfer
- 3-Phase Sequence
- Pre-Programming (0x10 02 / 0x27 / 0x28 / 0x85), Programming (0x34/0x36/0x37), Post-Programming (0x11)
- OTA Architecture
- Dual-Bank A/B flash partitioning with cryptographic signature verification and rollback safety