UDS Negative Response Code $76: illegalBlockSequenceCounter. Block sequence counter value violates protocol boundary conditions during data transfer. Typical cause: Sequence counter initialized to invalid value or skipped blocks during multi-packet stream. Recovery: Restart block transfer sequence starting strictly with sequence counter byte 0x01.

Technical Specifications

Negative Response Code
NRC $76
Standard Name
illegalBlockSequenceCounter
Category
Programming Negative Response Codes
Typical Cause
Sequence counter initialized to invalid value or skipped blocks during multi-packet stream
Recovery Guidance
Restart block transfer sequence starting strictly with sequence counter byte 0x01