U012A: Lost Communication With Chassis Control Module "A"
Lost Communication With Chassis Control Module "A". System: Network (Communication between ECUs), Subsystem: Network Communication Fault. The electronic module periodically expects cyclical broadcast frames from the node indicated by U012A. When cyclic heartbeat frames fail to arrive across the differential CAN-High / CAN-Low physical bus within the standard timeout deadline (typically 500ms - 1,000ms), a communication loss fault is logged and default fail-safe bus state is declared.